watts.comAutomatic Control ValvesThe Automatic Answer to Fluid Control
10413-21 (Globe) / 1413-21 (Angle)BOOSTER PUMP CONTROL / MECHANICAL LIFT CHECKSolenoid operated pump control for controlled opening and closingon pump
11513-6 (Globe) / 1513-6 (Angle)DEEP WELL PUMP CONTROLThe ACV 513-6 pump control valve starts in an open position duringpump start-up, purging the dee
RATE OF FLOWPRESSURE REDUCING114R (Globe) / 1114R (Angle)RATE OF FLOW (“R” indicates over the seat flow)Maintains a constant flow rate, adjustable, re
13115-2 (Globe) / 1115-2 (Angle)PRESSURE REDUCING / SUSTAININGAutomatically reduces a higher inlet pressure to a constant loweroutlet pressure regardl
14115-4 (Globe) / 1115-4 (Angle)PRESSURE REDUCING / SOLENOID ON-OFFAutomatically reduces a higher inlet pressure to a constant loweroutlet pressure re
15115-74 (Globe) / 1115-74 (Angle)PRESSURE REDUCING / LOW FLOW BY-PASS VALVEAutomatically reduces a higherinlet pressure to a constant loweroutlet pre
16116-31 (Globe) / 1116-31 (Angle)PRESSURE SUSTAINING / SOLENOID ON-OFFInstalled in a mainline it prevents upstream pressure from droppingbelow a pres
17SURGE RELIEF / CHECK116-52 (Globe) / 1116-52 (Angle)SURGE ANTICIPATOR RELIEF / REMOTE SENSEUsed in pumping systems to protect equipment from damagin
18ALTITUDE127-1 (Globe) / 1127-1 (Angle)ALTITUDE VALVE - ONE WAY FLOW (TANK FILL)Provides automatic filling of elevated tanks or reservoirs. When thea
19FIRE PROTECTION VALVES115F Globe / 1115F AnglePRESSURE REDUCING VALVE - UL LISTEDThe Watts ACV 115F (globe) and 1115F (angle) reducingvalve meets al
INTRODUCTION2Specifying Automatic Control Valves is a critical balancing act. On onehand, you must have the utmost confidence not only inthe quality a
20116FM (Globe) / 1116FM (Angle)FIRE PUMP RELIEF VALVEThe Watts ACV 116FM (globe) and 1116FM (angle) reliefvalve meets all the requirements for UL Lis
21FIRE PROTECTION VALVES100D-A GlobeDELUGE VALVE/PNEUMATIC - HYDRAULIC - UL LISTEDThe Watts ACV 100D-A deluge valve meets all requirementsfor UL Liste
1116FHFIRE HYDRANT RELIEF VALVEVALVE DESCRIPTIONProvides temporary relief protection to a water systemby attaching directly to a fire hydrant via 2-1/
23APPLICATIONS IN COMMERCIAL HIGH RISE - BUILDING110-14111611161116115115-7116-BYRDRAINCOOLING TOWERLABORATORYDENTISTAPARTMENTHOSPITALLAUNDRYKITCHENFL
FLOWFLOWNORMAL OPERATIONFAILED OPERATIONF115-PRV F116-PRV-BYR - SAFETY SHUTDOWNF115-PRV F116-PRV-BYR - SAFETY SHUTDOWNTo be piped to(Air Gap) DrainTo
25WATTS ACV 113-6RFPFLOOD PROTECTIONSHUTDOWN VALVEPROBLEMProperty damage due to relief valve discharge that canoccur due to dirt and debris within the
26Watts ACV Industrial Control ValvesWATTS ACV FEATURESStandard Production Valves:❘ Wide range of sizes 1-1/4" - 24"❘ Fused epoxy coating 10
Watts Series 813Irrigation ACV ValvesFeatures:★ Competitively priced★ Sizes 11⁄4" through 6"★ Line Serviceable★ Compact assembly★ Full range
28IRRIGATION CONTROL VALVES .
29IRRIGATION CONTROL VALVES
3TABLE OF CONTENTSPageTable of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3The More You Know . . . . . . . . . . . . .
ENGINEERING DATA / SIZINGINSTALLATION RECOMMENDATIONSAND REQUIREMENTSVERTICAL INSTALLATIONSAvoid mounting valves 6" and larger in a verti
VALVE SIZINGTo properly size an automatic control valve you need to know the following:• Highest and Lowest inlet pressures•Outlet pressure•Maximum fl
32PRESSURE DROP INDEX - PRESSURE REDUCING VALVESCalculate the pressure difference by subtracting the desired outlet pressure from the maximum inletpre
33AUTOMATICCONTROLVALVESUBMITTAL / SPECIFICATION8550 HANSEN RD, HOUSTON, TEXAS 77075 / PH 713-943-0688, FAX 713-944-9445DATE WATTS ACV REFERENCE # FIG
34The following indicated components are used on the WATTS ACV assembly listed above.Normal servicing can be accomplished by installation of elastomer
35To order the “right ACV”please provide the following:Refer to valve specifications beginning on page 6 andthe selected ACV # for detail list of stan
C-CACV 0310 MF10104 © Watts, 2011USA:Tel: (713) 943-0688 • Fax: (713) 944-9445 • Watts.comCanada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • Watts.
4THE MORE YOU KNOW ABOUT AUTOMATIC CONTROL VALVESTHE BETTER WATTS ACV LOOKS!Performance is standardThe design and innovative features incorporate
COMPETITIVE CROSS-REFERENCE GUIDEWatts ACV Cla-ValModel No. Model No. Description114 40-01 Rate of Flow Control Valve116 50-01 Pressure Relief Control
VALVE DIMENSION GLOBE ANGLESIZE 150# 300# 150# 300# THREADED THREADEDA 7 1/41 1/4 E 3 1/4F 1 7/8A 8 1/2 9 7.251 1/2 E44 1/4 3 1/4F44 1/4 1 7/8A 9 3/8
7110-10 (Globe) / 1110-10 (Angle)FLOAT CONTROL – MODULATING (CONSTANT LEVEL)The ACV 110-10 maintains a constant level in storage tanks andreservoirs.
8113-6 (Globe) / 1113-6 (Angle)SOLENOID ON/OFF (OPEN/CLOSE) WITH HIGHCAPACITY CONTROLSA 3-way solenoid and auxiliary 3-port accelerator cause the main
9PUMP CONTROL113-46 (Globe) / 1113-46 (Angle)BOOSTER PUMP CONTROL (Valves 4" and smaller)Solenoid operated pump control for controlled opening an